Show simple item record

dc.contributor.authorYin, Yong
dc.date.accessioned2009-05-15 19:10:44 (GMT)
dc.date.available2009-05-15 19:10:44 (GMT)
dc.date.issued2009-05-15T19:10:44Z
dc.date.submitted2009
dc.identifier.urihttp://hdl.handle.net/10012/4415
dc.description.abstractTransport parameter estimation and contaminant source identification are critical steps in the development of a physically based groundwater contaminant transport model. Due to the irreversibility of the dispersion process, the calibration of a transport model of interest is inherently ill-posed, and very sensitive to the simplification employed in the development of the lumped models. In this research, a methodology for the calibration of physically based computationally intensive transport models was developed and applied to a case study, the Reich Farm Superfund site in Toms River, New Jersey. Using HydroGeoSphere, a physically based transient three-dimensional computationally intensive groundwater flow model with spatially and temporally varying recharge was developed. Due to the convergence issue of implementing saturation versus permeability curve (van Genuchten equation) for the large scale models with coarse discretization, a novel flux-based method was innovated to determined solutions for the unsaturated zone for soil-water-retention models. The parameters for the flow system were determined separately from the parameters for the contaminant transport model. The contaminant transport and source parameters were estimated using both approximately 15 years of TCE concentration data from continuous well records and data over a period of approximately 30 years from traditional monitoring wells, and compared using optimization with two heuristic search algorithms (DDS and MicroGA) and a gradient based multi-start PEST. The contaminant transport model calibration results indicate that overall, multi-start PEST performs best in terms of the final best objective function values with equal number of function evaluations. Multi-start PEST also was employed to identify contaminant transport and source parameters under different scenarios including spatially and temporally varying recharge and averaged recharge. For the detailed, transient flow model with spatially and temporally varying recharge, the estimated transverse dispersivity coefficients were estimated to be significantly less than that reported in the literature for the more traditional approach that uses steady-state flow with averaged, less physically based recharge values. In the end, based on the Latin Hypercube sampling, a methodology for comprehensive uncertainty analysis, which accounts for multiple parameter sets and the associated correlations, was developed and applied to the case study.en
dc.language.isoenen
dc.publisherUniversity of Waterlooen
dc.subjectcalibrationen
dc.subjectuncertainty analysisen
dc.subjectcontaminant transporten
dc.subjectgroundwater flowen
dc.titleUncertainty Analysis and the Identification of the Contaminant Transport and Source Parameters for a Computationally Intensive Groundwater Simulationen
dc.typeDoctoral Thesisen
dc.pendingfalseen
dc.subject.programCivil Engineeringen
uws-etd.degree.departmentCivil and Environmental Engineeringen
uws-etd.degreeDoctor of Philosophyen
uws.typeOfResourceTexten
uws.peerReviewStatusUnrevieweden
uws.scholarLevelGraduateen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record


UWSpace

University of Waterloo Library
200 University Avenue West
Waterloo, Ontario, Canada N2L 3G1
519 888 4883

All items in UWSpace are protected by copyright, with all rights reserved.

DSpace software

Service outages