Show simple item record

dc.contributor.authorTurner, Jennifer
dc.contributor.authorPurslow, Christine
dc.contributor.authorMurphy, Paul J.
dc.date.accessioned2019-12-19 18:57:07 (GMT)
dc.date.available2019-12-19 18:57:07 (GMT)
dc.date.issued2019-01
dc.identifier.urihttps://doi.org/10.1097/ICL.0000000000000496.
dc.identifier.urihttp://hdl.handle.net/10012/15353
dc.description.abstractObjectives: To assess the efficacy and effect on clinical signs of a polyvinylsiloxane (Tresident; Shütz Dental Group GmbH, Germany) compared with an irreversible hydrocolloid (Orthoprint; Zhermack SpA, Badia Polesine, Italy) for ocular impression-taking. Methods: Twenty subjects were recruited (13 female and 7 male), with mean age 31.1±4.6 years (SD) (range 25.8–39.7). Subjects attended for 2 sessions, each of 1-hr duration, on 2 separate days. Each session was scheduled at the same time on each day. At each visit, the subject underwent an ocular impression procedure, using either Tresident or Orthoprint, in random order and to one eye only. Investigator 2 was blind to this assignment. Two experienced practitioners conducted the study, investigator 1 performed the ocular impression procedures and investigator 2 observed and assessed the clinical signs: logMAR visual acuity, ocular surface staining, tear break-up time (TBUT), and ocular hyperemia. Results: Visual acuity was unaffected by either material; TBUT was marginally disrupted by both materials, but was not clinically significant according to published criteria; ocular redness increased with both materials; and corneal staining was significantly greater after Orthoprint impression. Less redness and clinically insignificant staining after impression-taking, with fewer clinical complications, was found after use of Tresident. Conclusions: Tresident offers a quicker, more effective, and clinically viable method of obtaining ocular impression topography compared with the traditional Orthoprint, and Orthoprint causes significantly more superficial punctuate staining of the corneal epithelium than Tresident.en
dc.language.isoenen
dc.publisherWolters Kluweren
dc.titleOcular impression-taking - which material is best?en
dc.typeArticleen
dcterms.bibliographicCitationTurner, Jennifer, Christine Purslow, and Paul Murphy. “Ocular Impression-Taking—Which Material Is Best?” Eye & Contact Lens: Science & Clinical Practice 45, no. 1 (January 2019): 55–60. https://doi.org/10.1097/ICL.0000000000000496.en
uws.contributor.affiliation1Faculty of Scienceen
uws.contributor.affiliation2School of Optometry and Vision Scienceen
uws.typeOfResourceTexten
uws.peerReviewStatusRevieweden
uws.scholarLevelFacultyen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record


UWSpace

University of Waterloo Library
200 University Avenue West
Waterloo, Ontario, Canada N2L 3G1
519 888 4883

All items in UWSpace are protected by copyright, with all rights reserved.

DSpace software

Service outages