Gatti, Christopher J.Dickerson, Clark R.Chadwick, Edward K.Mell, Amy G.Hughes, Richard E.2022-01-122022-01-122007-07https://dx.doi.org/10.1016/j.clinbiomech.2007.02.001http://hdl.handle.net/10012/17861The final publication is available at Elsevier via http://dx.doi.org/10.1016/j.clinbiomech.2007.02.001. © 2007. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/Background The ability of mathematical models of the shoulder to accurately replicate physiological muscle moment arms is unknown. The purpose of this study was to compare model-predicted and experimentally measured moment arms for the rotator cuff muscles during arm elevation. Methods Moment arms obtained from six mathematical models and seven experimental studies were compared for the supraspinatus, infraspinatus, teres minor, and subscapularis for elevation in the scapular plane. Results All of the included models generated moment arms that generally fell within the range of experimentally measured data. Interpretation The quantitative agreement between model-predicted and experimentally measured moment arms supports the use of the included models for biomechanical shoulder analyses.enAttribution-NonCommercial-NoDerivatives 4.0 Internationalshouldermoment armscomputational modelComparison of model-predicted and measured moment arms for the rotator cuff musclesArticle